Setting terminals & Current Direction

Setting the current direction in a two-limb gapped inductor with TRAFOLO

In TRAFOLO, users can set the winding direction by setting the excitation direction (current, voltage) across the winding. There are two methods to achieve this in TRAFOLO:

  1. Swapping Terminals Visually in the ElMag tab
  2. Swapping Nodes/Indices in the Circuits tab

Swapping Terminals in ElMag Tab

Terminals can be visually identified in ElMag. Orange terminal represents Positive, Black terminal represents negative, and Grey elements represent Undefined terminals (considered as disconnected terminals).

Clicking on the colored section of the winding changes the terminal type, allowing the excitation (current, voltage) direction to be set up as needed.

Changing terminals using ElMag tab
Changing terminals to set the excitation direction using the ElMag tab

Swapping Indices in Circuits Tab

The terminals in the Circuit section are specified by their nodes or indices. Swapping these indices effectively exchanges the component terminals. This action reverses the current direction through the component.

Changing terminal using Circuits tab
Changing terminal indices to set the excitation direction using the Circuits tab
Was this page helpful?